°C
-50 to 60
%
1 to 100

Cross and counterflow plate heat exchanger with frost protection

m3/s
0.1 to 50
m3/s
0.1 to 50
deg C
-50 to 50
kg/kg
0.0001 to 0.030
deg C
10 to 35
kg/kg
0.001 to 0.025
deg C
10 to 35
deg C
0 to 5
deg C
0 to 5
m3/s
0.1 to 50
-
0.1 to 0.99
m/s
0.5 to 5.0
kg/kg
0.001 to 0.020
deg C
15 to 30

Condensation, hygroscopic, or sorption rotor with moisture recovery

m3/s
0.1 to 50
m3/s
0.1 to 50
deg C
-50 to 50
kg/kg
0.0001 to 0.030
deg C
10 to 35
kg/kg
0.001 to 0.025
deg C
10 to 35
deg C
0 to 5
deg C
0 to 5
m3/s
0.1 to 50
-
0.1 to 0.99
-
0.0 to 0.99
m/s
0.5 to 5.0
kg/kg
0.001 to 0.020
kW
0.01 to 2.0

Sensible heat recovery with circulation pump

m3/s
0.1 to 50
m3/s
0.1 to 50
deg C
-50 to 50
kg/kg
0.0001 to 0.030
deg C
10 to 35
kg/kg
0.001 to 0.025
deg C
10 to 35
deg C
0 to 5
deg C
0 to 5
m3/s
0.1 to 50
-
0.1 to 0.99
m/s
0.5 to 5.0
kg/kg
0.001 to 0.020
deg C
15 to 30
kW
0.01 to 5.0

Water heating coil or electric heater

m3/s
0.1 to 50
deg C
-50 to 50
deg C
10 to 35
deg C
0 to 5
deg C
0 to 3
deg C
-30 to 40
kg/kg
0.0001 to 0.025

Temperature or moisture control mode with optional reheater

m3/s
0.1 to 50
deg C
-50 to 50
deg C
10 to 35
kg/kg
0.001 to 0.025
deg C
0 to 5
deg C
-30 to 50
kg/kg
0.0001 to 0.030

Adiabatic humidification with water pump

m3/s
0.1 to 50
kg/kg
0.001 to 0.025
kg/kg
0.0001 to 0.025
kW
0.01 to 5.0
kg/kg
0.0001 to 0.010
-
1.0 to 10.0

Electric, gas-fired, or central steam humidifier

m3/s
0.1 to 50
kg/kg
0.001 to 0.025
kg/kg
0.0001 to 0.025
-
1.0 to 10.0

Indirect evaporative cooling via exhaust-side humidification + PHE

m3/s
0.1 to 50
m3/s
0.1 to 50
deg C
-50 to 50
kg/kg
0.0001 to 0.030
deg C
10 to 35
kg/kg
0.001 to 0.025
deg C
10 to 35
deg C
0 to 5
deg C
0 to 5
m3/s
0.1 to 50
-
0.1 to 0.99
m/s
0.5 to 5.0
kg/kg
0.001 to 0.020
deg C
15 to 30
-
0.1 to 0.99
kW
0.01 to 5.0
-
1.0 to 10.0

Plate heat exchanger with mixing section (PHE only)

m3/s
0.1 to 50
m3/s
0.1 to 50
deg C
-50 to 50
kg/kg
0.0001 to 0.030
deg C
10 to 35
kg/kg
0.001 to 0.025
deg C
10 to 35
deg C
0 to 5
deg C
0 to 5
-
0.1 to 0.99
m/s
0.5 to 5.0
kg/kg
0.001 to 0.020
deg C
15 to 30
m3/s
0.1 to 50
m3/s
0.1 to 50
m3/s
0.1 to 10

Supply and exhaust fan with VSD motor efficiency model

m3/s
0 to 50
m3/s
0 to 50
m3/s
0.1 to 50
m3/s
0.1 to 50
kW
0.1 to 500
kW
0.1 to 500
Pa
0 to 2000
Pa
0 to 2000
Pa
0 to 2000
Pa
0 to 2000
Pa
0 to 500
kW
0.1 to 500
kW
0.1 to 500
kW
0.1 to 500

Configuration
AHU Parameters
Air Flow
m3/s
m3/s
Heat Recovery
m/s
kW
kW
Design Conditions (freeze protection & humidifier)
kg/kg
deg C
kg/kg
Heating & Cooling
Humidification
kW
Fans
kW
kW
Pa
Pa
Pa
Pa
Pa
kW
kW
kW
Mixing Section (Configs 10-15)
m3/s
Temperature/Moisture Scenarios
Supply temperature = f(outdoor temp): 4 breakpoints
Extract temperature = f(outdoor temp): 3 breakpoints
Supply moisture = f(outdoor moisture): 4 breakpoints
g/kg
Operating Schedule
Select a preset schedule. The 7x24 grid is filled automatically.
Economic Parameters
years
EUR
EUR/kWh
EUR/kWh
EUR/kWh
EUR/kWh
EUR/kg
EUR
(1-8760, 0=off)